Digital Spring tester
1. High precision and high resolution: accuracy 1, minimum reading 0.001N;
2. Three display options: real-time, peak, and automatic peak;
3. Three conversion units: N, kg, lb
4. Peak hold function: capture the test peak;
5. Comparison function: the upper and lower limits are set freely, and the alarm lights automatically alarm for traffic lights and peaks;
6. Automatic peak value function: the peak value holding time (1~99 seconds) can be set freely;
7. Automatic shutdown function: 0~99 minutes without operation automatic shutdown (0 seconds without automatic shutdown);
8. Gravity acceleration function: According to different regions, it can be set freely (9.000~9.999);
9. Calculation function: connected to a computer, it can automatically calculate the maximum value, minimum value and average value of each test;
10. Built-in printer: can print 99 groups of stored measurement data and maximum, minimum, average, etc.
Model Number | ATH-10 | ATH-20 | ATH-30 |
Maximum testing load | 10N | 20N | 30N |
Minimum resolution | 0.001N | ||
Diameter of the platen | 34mm | ||
Maximum free length of
measurable spring |
80mm | ||
Length of travel o displacement scale |
60mm | ||
Division value of the
Displacement scale |
0.01mm | ||
Indication error | ±1% | ||
Power Supply | AC 110-220V, 50HZ-60HZ | ||
Power Capability
(without printer) |
13W | ||
Power capability
(with printer) |
20W | ||
Working temperature | 20±10℃ | ||
Temperature of storage and
transportation |
-27℃~+70℃ | ||
Relative temperature | 15%~80%RH |
Model Number | ATH- 100 | ATH- 150 | ATH- 200 | ATH- 300 | ATH- 500 |
Maximum testing load | 100N | 150N | 200N | 300N | 500N |
Minimum resolution | 0.01N | ||||
Diameter of the platen | 48mm | ||||
Maximum free length
of measurable spring |
150mm | ||||
Length of travel
of the displacement scale |
90mm | ||||
Division value of
the displacement scale |
0.01mm | ||||
Indication error | ±1% | ||||
Power Supply | AC 110-220V, 50HZ-60HZ | ||||
Power capability
(without printer) |
13W | ||||
Power capability
(with printer) |
20W | ||||
Working temperature | 20±10℃ | ||||
Temperature of storage
and transportation |
-27℃~+70℃ | ||||
Relative temperature | 15%~80%RH |
Model Number | ATH-1000 | ATH-2000 | ATH-3000 | ATH-5000 |
Maximum testing load | 1000N | 2000N | 3000N | 5000N |
Minimum resolution | 0.1N | |||
Diameter of the platen | 108mm | |||
Maximum free length
of measurable spring |
200mm | |||
Length of travel of the
displacement scale |
150mm | |||
Division value of the
displacement scale |
0.01mm | |||
Indication error | ±1% | |||
Power Supply | AC 110-220V, 50HZ-60HZ | |||
Power capability
(without printer) |
13W | |||
Power capability
(with printer) |
20W | |||
Working temperature | 20±10℃ | |||
Temperature of storage
and transportation |
-27℃~+70℃ | |||