Laboratory Digital Balance Scale Price - Digital Desktop laboratory centrifuge – NANBEI
ND4C Technical Parameters Max speed: 4000rpm Max RCF: 2000xg Max volume 8*15ml Noise: ≤45dBA Timer 0~99min Weight: 8KG Dimension(LxWxH): 275*300*250mm Power supply AC 220V 50HZ Speed accuracy: ±20rpm Package carton box Matched Rotors for ND4C Order No. Rotor No. Max Speed (rpm) Max Volume(ml) Max RCF (g) NO35701 Angle Rotor 4000 8*15ml 1880 NO35702 Angle Rotor 4000 6*15ml 1880 NO31602 Angle Rotor 4000 12*7ml 1880 NO32666 Angle Rotor 4000 8*20ml 1800 ... -
Laboratory Vortexer Factories - Gentier 48E real time PCR machine – NANBEI
Parameters Model Gentier48E Thermal block Sample capacity(wells) 48 Reaction volume 5-100ul Consumables 0.2ml 8-strip tubes,0.2ml PCR single tube(Optical flat cap. Clear tube) Temperature range 0℃-100℃ Heating/cooling system Peltier Max heating rate 8.0℃/sec Average heating rate 6.0℃/sec Max cooling rate 5.5℃/sec Average cooling rate 4.0℃/sec Temperature accuracy ±0.1℃ Temperature uniformity ±0.1℃ Gradient range 1℃-40℃ Gradient block 8row Special temper... -
Laboratory Agricultural Equipment Factories - Table Top Aflatoxin Tester – NANBEI
Technical parameter Minimum detection volume 0ng Measuring range ≥0ng / ml (ppb) Absorbance range -0.041 ~ 1.999 (A) Concentration range -0.000 ~ 9999 Wavelength 330 ~ 900nm (this instrument only with 450 ± 2 nm interference filter) Sensitivity <0.1ng / ml Accuracy ± 0.1ng / ml Test time 20samples/hour Light source LED 3.6V / 20mA Use of the environment Temperature: 5 ~ 35 ℃; Humidity: ≤ 85% Bright current stability ≤ 0.3t (T) / 5 minutes Dark current stabilit... -
Buy Digital Force Gauge Manufacturers - Digital Colorimeter tester – NANBEI
Introduction Device sensor is from Japan and information processing chip is from USA, which guarantee the optical signal transfer accuracy and electrical signal stability. Display accuracy is 0.01, repeated test accuracy △E deviation value is below 0.08. 2. Multiple color space display color values : L*a*b、L*c*h、Yxy Being the most commonly used testing device, our colorimeter with built-in color display indicators transformation program, which makes our device could be used for color t... -
Buy Kjeldahl Nitrogen Analyzer Price - Low Speed PRP Centrifuge – NANBEI
Features 1. Using brushless DC variable frequency motor, no dust, no maintenance, large torque, fast lifting speed. 2. Using microcomputer processor to accurately control, LED display speed, centrifugal force, time and other parameters, easy to operate. 3. The door cover has an independent motor servo, which reduces the labor intensity of the operator, and protects the overspeed unbalance. The body adopts high-quality steel structure; it is safe and reliable, and more convenient to use. ... -
Laboratory Conductivity Meter Factory - Benchtop pH meter – NANBEI
Function 1.Large screen, LCD display,dual parameter 2.Automatic buffer recognition and two-point calibration 3.It has the function of manual temperature compensation. 4.It is equipped with E-201-C pH combined electrode. Product parameter MODEL Specifications PHS-3C Accuracy grade 0.01 Parameters pH, mV(ORP), temperature Measuring range pH (0.00~14.00) pH mV (-1999~1999) mV Temp (0.0~99.9) ℃ Resolution pH 0.01pH mV 1mV Temp 0.1℃ Accuracy pH ±0.01pH mV ... -
Buy Ult Freezer Manufacturers - -40 degree 450L low temperature freezer – NANBEI
Features 1.The digital temperature display can indicate operating status clearly 2.The high-precision microcomputer temperature control system enables users to set the temperature inside the cabinet within a range from -20℃ to -40℃ 3.The environmentally friendly Freon-free refrigerant and high-efficiency enclosed compressor supplied by a famous brand can ensure energy saving and low noise The condenser installed on 4.the bottom ensures temperature stability and system reliability 5.The C... -
-
Buy Grain Moisture Meter Factories - digital grain moisture meter – NANBEI
Features 1. Automatic weighing; automatic temperature compensation; automatic moisture test; 2. Automatic power off, automatic moisture test. 3. Empty machine to correct moisture; the latest salary model 4. The user can calibrate and correct errors. Testing field seeds Round rice, rapeseed meal, soybeans, grain feed, wheat, sunflower seeds, rapeseed, large watermelon seeds, corn, small watermelon seeds, barley, carrot seeds, long rice, black sesame, rice, yellow sesame, soybean meal... -
Laboratory Blood Storage Refrigerator Price - 330L 2 to 8 degree pharmacy refrigerator – NANBEI
Usage Professional refrigeration equipment for refrigerating medicines in the medical industry can also be used to store biological products, vaccines, medicines, reagents, etc. It is suitable for waiting in pharmacies, pharmaceutical factories, hospitals, disease prevention and control centers, community health service centers, and various laboratories. Main features 1. Working conditions: ambient temperature 16-32℃, ambient humidity: 20-80%, voltage: 220V±10%, frequency 50±1H... -
Buy Water Jacket Incubator Price - Chemical Vacuum drying oven – NANBEI
introduce The vacuum drying oven is specially designed for drying heat-sensitive, easy-to-classify and easy-to-chemical substances. When working, it is sucked into the working chamber to maintain a certain vacuum, and can be filled into the body concentration, especially some complex items can also be dried quickly. Intelligent digital temperature regulator for temperature setting, display and control. Features 1.digital display microprocessor temperature controller and timing funct... -
Laboratory Thermocycler Factories - nucleic acid extractor analyzer – NANBEI
Features Can be controlled via Android system smart phones or tablets by connecting to the built-in wifi of Libex; or simply via the screen and buttons of the instrument. 3 throughput modules available for greater flexibility in sample throughput and processing volume. Built-in UV disinfection module; ultra-silent operation. Technical Parameter Product Model Libex Authoritative Certifications: NMPA, CE, KFDA, etc. Sample Throughput 1-15 1-32 1-48 Processing Volume 50—1500 μ...