Laboratory Atomic Absorption Spectrophotometer Manufacturers - Full-range ION Chromatograph – NANBEI
Laboratory Atomic Absorption Spectrophotometer Manufacturers - Full-range ION Chromatograph – NANBEI Detail:
Technology advantage
1.Built-in circulating 3D constant temperature technology(CN 204259917U)
Temperature stability time is less than 30 mins, ensuring the accuracy and reliability of test data.
2.The world’s leading full-range series of ion chromatographic columns(CN 105126936A、CN 104788603A)
High efficiency, large capacity of the columns for detecting ions of varied compositions.
3. Self-Regenerating Electrolytic Micro-membrane Suppressor(CN 102735792A)
High pressure resistance, small dead volume, highly responsive to signals.
4. Auto-range Conductivity Detector
It can directly detect the signal from ppb to ppm without adjusting the range; Only one conductivity detector can detect anions and cations.
5. Observatory intelligent workstation
Integrated control;With intelligent start-up, shutdown and maintenance functions;Compatible with a variety of instruments;Customized images.
Technical Parameter
Ion Chromatographic Pump |
Type |
High-pressure and low-pulse two-piston tandem advection pump |
Maximum Pressure |
35MPa(PEEK) |
|
Pressure Display Accuracy |
≤0.1MPa |
|
Flow Stability |
(0.2-0.5)mL/min≤3%; (0.5-1.0)mL/min≤2%; >1.0mL/min≤2%; |
|
Allowable Deviation of Flow |
(0.2-0.5)mL/min , ±5%; (0.5-1.0)mL/min, ±3%; >1.0mL/min, ±2%; |
|
Flow Range |
0.001~9.999mL/min |
|
Pressure Pulse |
≤0.5% |
|
Flow Precision | ≤0.1% |
|
Flow Accuracy | ≤0.1% |
|
Manual Sample Injector |
Maximum Pressure |
35MPa |
External Diameter of the Tube | 1/16″ | |
Contact Material of the Rotor | PEEK | |
Contact Material of Medium | PEEK/Ceramics | |
Column Heater
|
Operating Temperature Range | 20~60℃(68~140℉) |
Controlling Temperature Accuracy | ±0.01℃ | |
Allowable Deviation of Column Heater’s Temperature | ±1℃ | |
Temperature Stability | ≤0.05℃/h | |
Conduction Detection System |
Type | Constant temperature auto-range conductivity detector |
Cell Volume | ≤0.8μL | |
Detection Range | 0~35000μS/cm | |
Detection Resolution | ≤0.0020nS/cm | |
Output Voltage | -6000+6000mv(adjustable) | |
Electronic Noise | 0.02nS | |
Baseline Noise | ≤0.001μS/cm | |
Baseline Drift | ≤0.02μS | |
Operating Temperature Range | Room temperature +5℃~60℃(41 ~140℉) | |
Controlling Temperature Accuracy | ±0.01℃ | |
Temperature Compensation | 1.7 %/℃ | |
Maximum Pressure | 10.0MPa | |
Linear Range | ≥103 | |
Instrument Linearity | ≥0.999 | |
Quantitative Repeatability | ≤1.0% | |
Qualitative Repeatability | ≤0.5% | |
Minimum Detectable Concentration | Cl-≤0.0005ug/mL; Li+≤0.001ug/mL; BrO3-≤0.001ug/mL; |
|
Flow System | Plastic Flow Path | Made of PEEK materials |
Six-way Valve | PEEK material, pressure 5000psi; Independent automatic collecting and flow function. |
|
Suppressor | Type | Self-Regenerating electrolytic micro-membrane suppressor |
Maximum Pressure | 6.0MPa | |
Dead Volume | <50μL | |
Power Supply | 150W | |
External Size(L*W*H*) | 325*400*500 | |
Net Weight(KG) | 21 | |
Gross Weight(KG) | 28 |
Product detail pictures:
Related Product Guide:
Innovation, excellent and reliability are the core values of our company. These principles today much more than ever form the basis of our success as an internationally active mid-size business for Laboratory Atomic Absorption Spectrophotometer Manufacturers - Full-range ION Chromatograph – NANBEI , The product will supply to all over the world, such as: Niger, panama, Estonia, As an experienced factory we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of the company is to live a satisfactory memory to all the customers, and establish a long term win-win business relationship. For more information, please contact us. And It is our great pleasure if you like to have a personally meeting in our office.