How to extend the service life of video microscope

How to extend the service life of video microscope

Video microscope, which converts the physical image seen by the microscope through digital-to-analog conversion, so that it can be imaged on the screen of the microscope or on the computer. Video microscope is a high-tech product successfully developed by combining sophisticated optical microscope technology, advanced photoelectric conversion technology, and liquid crystal screen technology. Therefore, we can change the research on the microscopic field from the traditional ordinary binocular observation to the reproduction on the display, thereby improving the work efficiency.
When using a video microscope, you should pay attention to the correct operation, so that the life of the microscope will be long. As for the precautions, let’s take a look together:
1. It is strictly forbidden to pick up the microscope with one hand.
2. If it is necessary to move the microscope, be sure to lift the microscope and put it in an appropriate position. It is strictly forbidden to push the microscope (the vibration caused by the push may cause the internal parts of the microscope to loosen, remember!), please handle the microscope with care.
3. When using a microscope, the height of the chair should be appropriate. When observing, you should get used to observing with both eyes at the same time, and the aperture and brightness of the light source should be appropriate. Otherwise, you will easily feel tired when observing for a long time.
4. Be sure to lower the stage to the lowest point when turning the rotating disk, so as not to scratch the lens of the eyepiece due to improper operation.
5. The slide should be removed for specimen staining or any other operation, and then put back on the stage for observation after the operation is completed. Do not operate on the stage to prevent dye or other liquids from flowing into the microscope or damaging the lens.
6. After observing one material, when you want to change another material, be sure to lower the stage to the lowest point, and then refocus according to the standard procedure after changing the glass slide. Do not directly replace the specimen to avoid scratching the lens or slide specimens.
7. After using the microscope, the stage should be lowered to the lowest point, and the low-magnification lens should be aligned with the central hole of the stage. The power cord should be rolled up, covered with a dust cover, and stored in a storage cabinet.


Post time: Dec-08-2022